Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Rev. latinoam. enferm. (Online) ; 28: e3299, 2020. tab, graf
Artigo em Inglês | BDENF, LILACS | ID: biblio-1126959

RESUMO

Objective: to evaluate the use of the 2D-FlexRuler as a facilitating tool for the early calculation of the predictive scar factor of chronic wounds. Method: a descriptive study with a quantitative, experimental, longitudinal and prospective approach. The sample consisted of 22 outpatients. 32 chronic wounds were analyzed. The wound edges were identified and drawn on the 2D-FlexRuler. The calculations of the areas of chronic wounds were obtained by manual, traditional methods, by software and Matlab algorithm. These areas were compared with each other to determine the efficiency of the proposed ruler in relation to traditional methods. Results: the calculation of the wound area by the traditional method and Kundin's coefficient show average errors greater than 40%. The manual estimation of the area with the 2D-FlexRuler is more accurate in relation to traditional measurement methods, which were considered quantitatively disqualified. When compared with the reference method, for example, the Klonk software, the data obtained by 2D-FlexRuler resulted in an error of less than 1.0%. Conclusion: the 2D-FlexRuler is a reliable metric platform for obtaining the anatomical limits of chronic wounds. It facilitated the calculation of the wound area under monitoring and allowed to obtain the scar predictive factor of chronic wounds with precocity in two weeks.


Objetivo: avaliar o uso da régua 2D-FlexRuler como ferramenta facilitadora para o cálculo precoce do fator preditivo cicatricial de feridas crônicas. Método: estudo descritivo com abordagem quantitativa, experimental, longitudinal e prospectiva. A amostra foi de 22 pacientes ambulatoriais. Foram analisadas 32 feridas crônicas. As bordas das feridas foram identificadas e desenhadas na 2D-FlexRuler. Os cálculos das áreas das feridas crônicas foram obtidos pelos métodos manuais, tradicionais, por softwares e algoritmo Matlab. Essas áreas foram comparadas entre si para determinar a eficiência da régua proposta em relação aos métodos tradicionais. Resultados: o cálculo da área da ferida pelo método tradicional e coeficiente de Kundin demonstram erros médios maiores do que 40%. A estimativa manual da área com a 2D-FlexRuler é mais exata em relação aos métodos tradicionais de medição, os quais foram considerados quantitativamente desqualificados. Quando comparada com o método de referência, i.e., o software Klonk, os dados obtidos pela 2D-FlexRuler resultaram em um erro menor que 1,0%. Conclusão: a régua 2D-FlexRuler é uma plataforma métrica confiável para a obtenção dos limites anatômicos de feridas crônicas. Facilitou o cálculo da área da ferida sob monitoramento e permitiu obter o fator preditivo cicatricial de feridas crônicas com precocidade em duas semanas.


Objetivo: evaluar el uso de la regla 2D-FlexRuler como herramienta facilitadora para el cálculo temprano del factor predictivo de cicatrices en heridas crónicas. Método: estudio descriptivo con enfoque cuantitativo, experimental, longitudinal y prospectivo. La muestra consistió en 22 pacientes ambulatorios. Se analizaron 32 heridas crónicas. Los bordes de la herida fueron identificados y dibujados en 2D-FlexRuler. Los cálculos de las áreas de heridas crónicas se obtuvieron por métodos manuales, tradicionales, por software y algoritmo Matlab. Estas áreas se compararon entre sí para determinar la eficiencia de la regla propuesta en relación con los métodos tradicionales. Resultados: el cálculo del área de la herida por el método tradicional y el coeficiente de Kundin muestran errores promedio superiores al 40%. La estimación manual del área con 2D-FlexRuler es más precisa en relación con los métodos de medición tradicionales, que se consideraron descalificados cuantitativamente. Al ser comparados con el método de referencia, es decir, el software Klonk, los datos obtenidos por 2D-FlexRuler arrojaron un error de menos del 1,0%. Conclusión: la regla 2D-FlexRuler es una plataforma métrica confiable para obtener los límites anatómicos de las heridas crónicas. Facilitó el cálculo del área de la herida bajo monitoreo y permitió obtener el factor predictivo de cicatriz de heridas crónicas con precocidad en dos semanas.


Assuntos
Pesos e Medidas , Cicatrização , Ferimentos e Lesões , Software , Cicatriz , Precisão da Medição Dimensional , Ferida Cirúrgica , Metronidazol
2.
Biosci. j. (Online) ; 34(5): 1402-1413, sept./oct. 2018.
Artigo em Inglês | LILACS | ID: biblio-967334

RESUMO

This study discusses the Brazilian model of incentives for the domestic development and production of supplies for public health, considering initiatives implemented from 2003 to 2016. This paper was prepared based on a qualitative bibliographic study, considering authors in the fields of health sciences, public health and public policy, reports by the World Health Organization (WHO), the Organization for Economic Cooperation and Development (OECD), Inter-American Development Bank (IDB) and the World Trade Organization (WTO), and official documents available from the Brazilian Federal Government. The paper focuses on the social dimension of health, considering a specific time period in the literature, from 2003 to 2016 and, finally, the new Regulatory Framework for Science, Technology, and Innovation approved in 2016. Various government initiatives were identified in the field of technological development and production to meet the objectives of the SUS according to the literature analysis. Brazil has been substantially increasing investment in Research and Development (R&D) during the last decade, though it lags European and OECD counterparts. Brazilian investment in R&D increased from 1.01% of gross domestic product (GDP) in 2000 to 1.23% in 2012. Despite being the top performer in Latin America (representing 60% of total R&D investment in the region), investment in R&D in Brazil is approximately half the level of European and OECD countries, which invest on average approximately 2% and 2.5% of GDP.


Este artigo pretende discutir o modelo brasileiro de incentivos para o desenvolvimento interno e produção de insumos para saúde pública, considerando ações governamentais implementadas no período de 2003 a 2016. O artigo foi elaborado com base em estudo bibliográfico qualitativo, considerando autores nas áreas de economia da saúde, saúde pública e políticas públicas, relatórios da Organização Mundial de Saúde (OMS), Organização para a Cooperação e Desenvolvimento Econômico (OCDE), Banco Interamericano de Desenvolvimento (IDB) e Organização Mundial do Comércio (OMC), bem como documentos oficiais disponíveis do Governo Federal Brasileiro. O estudo aborda a dimensão social da saúde, considerando um período de tempo específico na literatura, de 2003 a 2016 e, finalmente, o novo Marco Legal da Ciência, Tecnologia e Inovação aprovado em 2016. Diversas iniciativas governamentais para atingir os objetivos do SUS foram identificadas, de acordo com a análise da literatura. O Brasil tem aumentado substancialmente o investimento em Pesquisa e Desenvolvimento (P & D) durante a última década, embora fique atrás de países europeus e da OCDE. O investimento brasileiro em P & D aumentou de 1,01% do produto interno bruto (PIB) em 2000 para 1,23% em 2012. Apesar de ter o melhor desempenho na América Latina (representando 60% do investimento total em P & D na região), o investimento em P & D no Brasil é aproximadamente metade do nível dos países europeus e da OCDE, que investem em média aproximadamente 2% e 2,5% do PIB.


Assuntos
Política Pública , Sistema Único de Saúde , Desenvolvimento Tecnológico , Saúde Pública , Ciências da Saúde
3.
Rev. educ. fis ; 24(2): 305-315, Aprl.-June 2013. graf, tab
Artigo em Português | LILACS | ID: lil-701516

RESUMO

Diversas técnicas foram, e estão sendo, desenvolvidas para a identificação e adequação de possíveis problemas no sistema esquelético dos indivíduos. Esta revisão tem por finalidade descrever os principais métodos de diagnóstico postural da coluna lombar. Diversos descritores relacionados ao tema foram utilizados nas bases de dados ISI Web of knowledgeSM, SCOPUS, SciELO e Pubmed. Os resultados apresentam as vantagens de limitações dos métodos: Radiografia, Técnica de avaliação postural por imagem ou fotometria, Técnica quadro de referência postural (PRF), Goniometria, Plataforma de Força, Ultrassonografia, Spinal Mouse, Ressonância magnética, Cinemática e Eletromiografia (EMG). Pode-se verificar que as técnicas de maior facilidade são a Fotometria, a Técnica quadro de referência postural (PRF), Plataforma de força e Goniometria. Por outro lado, apesar de serem pouco aplicáveis, a(s) técnica(s): Radiografia, Spinal Mouse, Ressonância magnética, Cinemática, Eletromiografia (EMG) e o Ultrassom são as que apresentam maior precisão na medida da curvatura lombar.


Several techniques have been and are being developed for the identification and adequacy of potential problems in the skeletal system of individuals. This review aims at describing the main methods for posture diagnosis of the lumbar spine. Several descriptors related to the topic were used in databases ISI Web of KnowledgeSM, SCOPUS, SciELO, and Pubmed. We presented the benefits of limitations of methods: Radiography, Postural Assessment Technique by imaging or photometry, Postural Reference Frame Technique (PRF), Goniometry, Power Platform, ultrasound, Spinal Mouse, Magnetic Resonance Imaging, Kinematics, Electromyography (EMG). The easiest techniques were: photometry, postural reference frame technique (PRF), Power Platform and Goniometry. On the other hand, though rarely applied, Radiography, Spinal Mouse, Magnetic Resonance Imaging, Kinematics, Electromyography (EMG) and ultrasound were those with greater accuracy in measuring lumbar curvature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA